| Syntax |
$AA3NVV[CHK](cr)
| $ |
a delimiter character |
| AA |
address of setting module (00 to FF) |
| 3 |
command for trim output
|
| N |
specificed channel for calibration |
| VV |
trim value, 00 for no change, increase from 01 to 7F(+127), and
decrease from FF(-1) to 80(-128)
I-87022/26/24C/28C :
Type = 0/1, 4.88
uA each count
Type = 2, 2.44m V
each count
I-87024 :
Type = 30/31, 0.3uA each count
Type = 32/33/34/35, 0.15mV each count |
| [CHK] |
2 characters of Checksum |
| (cr) |
Character Return(0x0D) for denote the end of command |
|