Analog Input | Input Channel | 8 differential/16 single-ended input channels | |
Input Type |
|
||
Sampling Rate | 100K sample rate for single channel in polling mode, 50K sample rate for single channel in interrupt mode, 10K sample rate for 8 channels scan in interrupt mode. |
||
Accuracy | +/-0.1% | ||
Common Mode Rejection | typic 86dB | ||
Voltage Input Impedance | 20/200K/20M Ohms (Jumper Select) 200K(Default) |
||
Overvoltage Protection | -35V to +35V maximum | ||
Isolation Voltage | 3000Vrms | ||
LED Display |
1 LED as Power indicator 16 LEDs as High/Low Alarm signals |
||
Power Requirement | DC +5V, 480mA maximum |