****************************** Mar-29-2006 [v3.01] Change : There are functions reserved now, and new functions are provided to replace them. They have the same parameters. Old function New function ================ ================== P100X_Delay P100X_DelayTick P100X_Do P100X_DigitOut P100X_Di P100X_DigitIn P100X_SetChannelConfig P100X_SetChConfig P100X_Polling P100X_AdPollingH P100X_AdPolling P100X_AdPollingF P100X_AdsPolling P100X_AdMultiPollingF P100X_AdsPacer P100X_AdMultiPacer P100X_InstallIrq P100X_IntInstall P100X_GetBuffer P100X_IntGetBufferH P100X_GetFloatBuffer P100X_IntGetBufferF P100X_GetIntCount P100X_IntGetCount P100X_INT_AdStart P100X_IntStart P100X_ExtINT_AdStart P100X_IntStartExTrigger P100X_INT_AdStop P100X_IntStop, P100X_IntRemove The parameter of P100X_DigitOut() and P100X_DigitIn() functions have a little difference from the old ones. New function requires 4-byte data type to transfer 2-byte data, it is useful for programming languages whichs do not support unsigned data type. Change : Combines the DLL driver and OCX control in a single setup program. Change : Change the bus number limitation to 31. ****************************** Jan-26-2005 Add : Add external Interrupt function. ****************************** Mar-02-2000 Fix : Change the Interrupt-Architecture. Fix : Fix the declaration with prefix "P100X_". ****************************** Jul-17-1999 Update : Fix the demo programs of Interrupt Mode to prevents the GAP. (Don't draw the wave if the process canceled by user.) Update : Fix the declaration file for VC and BCB for adapt to C and C++ syntax. ****************************** May-15-1999 Update : Change the format of user manual to .PDF. The user may need to free download the Adobe Arcobat Reader at http://www.adobe.com/arcobat/ Add : Add the user manual "CallDLL.pdf", it describes how to call the DLL functions with VB, VC++, Delphi, BCB. Add : Add the user manual "ResCheck.pdf", it describes how to check the resoures on Windows 95/98/NT.