------------------------------------------------- eLogger Copyrightc ICP DAS Co., Ltd. All rights reserved. ------------------------------------------------- Version 2.0.0.0 [2020/01/03] by Mac - NEW: Support PC runtime. - NEW: Support string memory which can be used in list box to show messages. - NEW: You can use 30 tags of PC runtime/50 tags of PAC runtime for free. Request a free license key by the link. http://www.icpdas.com/products/Software/ez_data_logger/elogger_licensekey.html ƒÜ For more tags, please refer to the link for the ordering information. http://www.icpdas.com/products/Software/ez_data_logger/elogger_licensekey.html ==Runtime== For Runtime PC Version (PC Windows7/Windows10) The Hardkey is an encapsulated chip that must be physically connected to the USB Port of the local computer on eLogger runtime PC version is installed. For Runtime PAC Version (WinCE7) PAC Support : VP-1231-CE7/VP-4231-CE7/VP-6231-CE7 VP-2201-CE7/VP-3201-CE7/VP-4201-CE7/ VP-5201-CE7/VP-6201-CE7 WP-9221-CE7/WP-9421-CE7/WP-9821-CE7 WP-8121-CE7/WP-8421-CE7/WP-8821-CE7 WP-5231-CE7/WP-5231M-CE7 WP-2241M-CE7 For Runtime PAC Version (WES7) PAC Support : iPPC-4701-WES7/iPPC-6701-WES7/ iPPC-5701-WES7/iPPC-7701-WES7 iPPC-6731-WES7 XP-8031-WES7, XP-8131-WES7, XP-8331-WES7, XP-8731-WES7 XP-9171-WES7/XP-9371-WES7/XP-9771-WES7 XP-9181-WES7/XP-9381-WES7/XP-9781-WES7 ***eLogger no longer supports CE5 and CE6 after V2.0.0.0 ------------------------------------------------------------------------------------------------------------------ Version 1.6.6.0 [2018/02/15] by Renee ==Developer== -NEW: Support undo/redo/alignment when editing pages and webpages. -Modify: The way of saving project change from automatically save to manually save and add "Save" in the project menu. -Modify: Set default value of MouseControl property to true if tag type is AO or DO tag. -Bug Fix: Fix the bug that "Output Limit value(Max. and Min.)" always show default value even though user changed it. -Bug Fix: The shortcut key of Exit change from Ctrl+X to Alt+F4 to avoid conflicting with cut(Ctrl+X). -Bug Fix: Fix the bug that an error shows when using "Connectivity Check" in MySQLDataLog. -Bug Fix: Fix the bug that an unexpected error shows when using "Test SQL on Web" in RemoteDataLog. ==Runtime== -Modify: For RuntimeXPacWES, use pacnet.dll instead of XPacnet.dll. -Bug Fix: Fix the bug that RuntimeXPacWES can't run the ModuleOnSlot driver. -Bug Fix: Fix the bug that RuntimeXPacWES can't run MySQLDataLog procedure. ==Database Report== -NEW: Add "DB Report.exe" to query data in the MySQL or MS SQL database which is created by eLogger. ------------------------------------------------------------------------------------------------------------------ Version 1.6.5.0 [2018/11/13] by Renee -NEW: Webpage support new components: Chart, Linear Gauge and Radial Gauge. -NEW: Webpage support transparency. -Bug Fix: Fix odometer can't set analog output values.(HMI.dll) -Bug Fix: Fix switchLED would become smaller at each time when loading the page. -Bug Fix: Fix the error that when adding more than one plot. -Bug Fix: Fix the runtime errors in WinCE7 and WinCE6 platform. -Bug Fix: Fix the javascript using in the webpage to improve efficiency. -Bug Fix: Fix the size error of the seven segment. ------------------------------------------------------------------------------------------------------------------ Version 1.6.4.0 [2018/02/07] by Renee -NEW: RemoteMachine add "Connect" and "Disconnect" button. The step to upload the project is Connect->Upload Project & Webpages->Disconnect. -NEW: Layout size add "1920x1080" & "Customize". - Fix Bug: Fix some component's bug and loading and saving bug in Page and Webpage.(in Developer) - Fix Bug: Correct ModbusTCP driver can't write value correctly when using multi-register. - Fix Bug: Correct ModbusSerial driver can't write value correctly when using multi-register. - Fix Bug: Fix LocalDataLog.dll in runtime can't find FTP root after v1.6.3 when using RuntimeCE.exe. ------------------------------------------------------------------------------------------------------------------ Version 1.6.3.0 [2017/10/24] by Renee - NEW: Page component update. Label can set background color. Textbox can set font color. Textbox, Switch, Label, Button, Plot can set font style(bold, italic, strikeout, underline). - NEW: Webpage component update. Textbox, Switch, Label, Button, Plot can set font style(bold, italic, strikeout, underline). - NEW: Add a "Connection Test" button in the Remote Machine. - Adjustment: Modify MQTT Driver and make it fit to MQ-7200M modules. - Adjustment: Float can edit max and min value. - Adjustment: Modify no-effect of the edit menu in Chinese mode. - Adjustment: Merge RuntimeWinPacCE5.exe, RuntimeXPacCE6.exe and RuntimeCE7.exe to RuntimeCE.exe.. - Adjustment: Setthe default http root to Micro SD card when uploading project (Need to reboot the PAC). - Adjustment: Update ModbusTCP, ModbusSerial and ModuleOnSlot Driver. - Adjustment: Modify bug in LocalDataLog, MySQLDataLog and RemoteDataLog. - Adjustment: Merge the output webpage folder(CE5Web and CE6Web) to CEWeb. - Adjustment: Modify the Account Management in Runtime of WinCE7. ------------------------------------------------------------------------------------------------------------------ Version 1.6.2.0 [2016/02/22] by Renee - NEW: Support MQTT driver. - NEW: Support WinCE 7 for Runtime program. - Adjustment: Change the listening way for Modbus TCP Server. - Adjustment: Update ModbusTcp, ModbusSerial, ModuleOnSlot runtime driver. - Adjustment: Revise the way of checking the free disk space in LocalDataLog. - Adjustment: Revise the connecting way to sql server in the timer function in MySQLDataLog and RemoteDataLog runtime driver. ------------------------------------------------------------------------------------------------------------------ Version 1.6.1.0 [2015/07/31] by Renee - NEW: Support record to MySQL database. Enable the operation in [Procedure-> MySQLDataLog]. - Adjustment: RemoteMachine->Upload Web Pages is combined to Upload Project. When uploading web pages, only upload the pictures that are used in the porject. - Adjustment: Gain and Offset save incorrect values in Web Page is now correct. - Adjustment: The backup method in RemoteDataLog is changed to backup a table instead of a whole database. - Adjustment: The LocalDataLog can append data to the file instaed of creating a new file if the record headers are no change in log setting. ------------------------------------------------------------------------------------------------------------------ Version 1.6.0.0 [2015/07/14] by Renee - NEW: Support Microsoft SQL server. Enable the operation in [Procedure-> RemoteDataLog]. And the data in the SQL server can be queried on the Web. Support log data in the controller. Enable the operation in [Procedure-> LocalDataLog]. - NEW: eLogger Runtime program for background is included. To let the program run in the backgroud, minimize the program and it will appear in the toolbar. The path is eLogger/eLogger_Runtime_Background. - Adjustment: SQLCE Database is unsupported. - Adjustment: The "Upload Project" in the "Remote Machine" window also can upload the background pictures that is uesd in the pages to the PAC. - Adjustment: The username and password for the web pages can be set in the "Web Page" window. ------------------------------------------------------------------------------------------------------------------ Version 1.5.1.0 [2014/11/27] by Renee - Adjustment: The "Upload Web Pages" in the "Remote Machine" window can upload not only web pages but the pictures used in the web pages to the remote PAC. The formats of pictures support JPG, JPEG, GIF, PNG and BMP file extension. - Adjustment: The username and password of the web pages can be set in the "System" window. Version 1.5.0.0 [2014/08/27] by Renee - NEW: Support Web Page design Components supported by web page: text box, seveng segment, picture toggle, label, button. Version 1.4.0.0 [2012/08/31] by Mac - NEW: Support Modbus TCP Server You can enable/disable Modbus TCP Server in System setting. - NEW: Support ISAPI ISAPI provides request commands in URL and responses the shared memory¡¦s data. You can refer to the demo of web application, and android application. Version 1.3.0.0 [2011/06/28] by Mac - NEW: Support Module on slot. I-8K series: I-8017HW, I-8024W, and all I-8K DIO module. I-87K series: DI, DO, AI, AO, counter, frequency, DI with latch function. Support list: http://www.icpdas.com/products/PAC/winpac/io_support_list.htm - NEW: Support Modbus serial master. You can connect to M-7000, standard Modbus/RTU devices or Modbus/ASCII devices. - NEW: Support Modbus TCP master. You can connect to ET-7000, PET-7000 or standard Modbus TCP devices. - NEW: Support Remote Maintenance. You can use eLogger Developer's remote control function to Upload / Run / Stop the project through the Ethernet. - NEW: Support Account Management. Admin Power User User Open project Yes No No Start/Stop project Yes Yes No Set AO/DO values Yes Yes No Switching pages Yes Yes Yes - NEW: Support layout simulation. Version 1.2.0.0 [2010/06/04] by Mac - NEW: Support XP-8000-CE6 runtime. - NEW: Support HMI Components. Plot. Version 1.0.2.0 [2009/12/23] by Mac - NEW: Support WinPAC/ViewPAC runtime. - NEW: Support 87K Module on Slot. - NEW: Support Shared Memory. You can read/write the shared memory to get/set the hardware IO values by .NET or eVC program at the same time. - NEW: Support Tag Mapping. You can assign Tags to the shared memory address, scale the data to other unit. - NEW: Support Flexible HMI Page. - NEW: Support HMI Components. TextBox, Linear Gauge, Angular Gauge, Seven Segment, Tank, Thermometer, Slider, LED, Switch LED, Odometer, Label, Button. - NEW: Support SQLCE Database.